Everpure MRS-100CC-BL EV997363 Reverse Osmosis System

Features of the Everpure MRS-100CC-BL EV9973-63 Reverse Osmosis System include:

  • Part Number: EV9973-63 (Old EV9970-10)
  • Improves equipment life and performance by removing at least 90%+ of all dissolved solids that cause scale build-up 
  • Guards against taste and odor causing contaminants while removing dirt, particulates and dissolved minerals that can adversely affect taste of water and beverages 
  • Wall mount design allows flexible installation 
  • Reduces limescale build-up that can cause excessive machine downtime and increased maintenance costs 
  • Scale reduction reduces energy costs 
  • “CC” models introduce a small amount of hardness minerals back into the treated water 
  • This controlled re-mineralization is desirable for coffee and other applications that require some hardness to achieve optimum results 
  • Specifications:
    • Overall Dimensions: 30” H (34” H – CC Model) x 15” W (20.5” Wwith Prefilter) x 8“ D 762 mm H (864mm H – CC Model) x 381 mm W (521 mm W with Prefilter) x 203 mm D 
    • Voltages:
      • 115VAC/60Hz (NEMA 5-15P Plug) 
      • 230VAC/50Hz (“Schuko” CEE 7/7 Plug) 
      • 240VAC/50Hz (AS 3112 Plug) 
    • Inlet and outlet connection: 3/8″ OD tube connection 
    • Wastewater line connection: 1/4″ OD tube connection 
    • Service Flow Rate: Dependant on water pressure in storage tankand line size(s) to equipment 
    • Pressure Requirements:
      • Operating: 25 – 80 psi (172-552 kPa), non-shock 
      • Maximum Static: 100 psi (689 kPa), non-shock 
      • Water Supply: 0.7 gpm (2.7 lpm) 
    • Inlet Temperature: 40°F – 100°F (4-38°C) 
    • Inlet TDS: 1,500 ppm max recommended 
    • Operating Weight: 35 lbs. (15.9 kg.)(not including storage tanks)

Operation Tips

  • Change filter cartridges on a regular 6-month preventative maintenance program
  • Change RO cartridges on a regular 2-year preventative maintenance program
  • Change cartridges when capacity is reached
  • Always flush the filter cartridge at time of installation and cartridge change
  • Proper pre-treatment is required to control RO Cartridge (membrane) scale formation and/or fouling
    • Raw water hardness in excess of 7 grains per gallon should be softened
    • The raw water may contain particulates and the use of a pre-filter is recommended
  • Contact EVERPURE Technical Service for pre-treatment recommendations

Installation Tips

  • Choose a mounting location suitable to support the full weight of the system when operating
  • Deliming of equipment prior to application is recommended
  • Never use saddle valve for connection 
  • Use 3/8” (10 mm) water line
  • The water inlet must supply a minimum of 0.7 gpm (2.7 lpm)
  • Install vertically with cartridge hanging down and allow 2 inches above and below unit for cover removal and service access
  • Allow clearance to right of unit for optional prefilter
  • Refer to Installation, Operation & Maintenance Manual for cartridge flushing and RO start-up

Contact FilterPure at 1-800-942-7873 for additional product information.

Download the 

Everpure MRS-600HE EV9627-15 GS-215-RO Post Filter

Features of the Everpure MRS-600HE EV9627-15 GS-215-RO Post Filter:

  • Part Number: EV9627-15 
  • Post Filter for the MRS-600HE System 
  • Provides clear, fresh, quality ingredient water 
  • Overall Dimensions: Length: 11” Diameter: 2.5″ 
  • Inlet connection: 3/8” x Outlet connection: 3/8” 
  • Capacity: 8,950 gallons (33,879l) 
  • Service Flow Rate: Maximum 1 gpm (3.8 Lpm) 
  • Pressure Requirements: 10 – 125 psi (0.7 – 8.6 bar), non-shock

Provides clear, fresh, quality ingredient water. 100% coconut shell carbon delivers enhanced chlorine taste and odor reduction, which can cause coffee to taste bitter. 11″ in-line design is compact and installs out of sight behind equipment. Change cartridges on a regular 6 month preventative maintenance program. Change cartridges when capacity is reached or when pressure falls below 10 psi. Service flow rate must not exceed 1 gpm. Always flush the filter cartridge at time of installation and cartridge change.

Download the Everpure MRS-600HE EV9627-15 Post Filter Specification Sheet



Everpure EV9970-76 MRS-225BL Blended Reverse Osmosis System

Features of the Everpure EV9970-76 MRS-225BL Blended Reverse Osmosis System:

  • Mineral Reduction System generating 225 gallons per day. 
  • The BL Series features an adjustable blend valve, which allows custom tailoring of the dissolved mineral content in the treated water. 
  • This feature allows a controlled amount of raw water to be mixed with the Reverse Osmosis water to create a blend containing the desired level of TDS (Total Dissolved Solids). 
  • After blending, the water passes through a sub-micron carbon filter. This final filtration step removes tastes and odors, and insures delivery of ingredient quality water. 
  • “CC” models introduce a small amount of hardness minerals back into the treated water. 
  • Improves equipment life and performance by removing at least 90%+ of all dissolved solids that cause scale build-up.
  • Guards against taste and odor causing contaminants while removing dirt, particulates and dissolved minerals that can adversely affect taste of water and beverages. 


Specifications:

  • Overall Dimensions Inches : 38″ H x 15″ W x 8″ D. 
  • Overall Demensions Centimeters (CM): 96.5H X 38.1W X 20.3 D. Voltages:115VAC/60Hz (NEMA 5-15P Plug). 230VAC/50Hz (CEE 7/7 Plug). 240VAC/50Hz (AS 3112 Plug). 
  • Inlet and outlet connection: 3/8″ OD tube connection. 
  • Wastewater line connection: 1/4″ OD tube connection. 
  • Service Flow Rate: Dependant on water pressure in storage tank and line size(s) to equipment. 




Pressure Requirements: 

  • Operating: 25 – 80 psi (172-552 kPa), non-shock. 
  • Maximum Static: 100 psi (689 kPa), non-shock. 
  • Water Supply: 0.7 gpm (2.7 lpm). Inlet Temperature: 40F – 100F (4-38C). Inlet TDS: 1,500 ppm max recommended. 
  • Operating Weight: 35 lbs. (15.9 kg.)(not including storage tanks). 
  • REQUIRES STORAGE TANK – Everpure offers a complete line of storage tanks.

For more information on this product, contact FilterPure at 1-800-942-7873.


Download the Everpure EV9970-76 MRS-225BL Blended Reverse Osmosis System Specification Sheet

Everpure MRS-600HE-II EV9970-54 Reverse Osmosis System

Features of the Everpure MRS-600HE-II EV9970-54 Reverse Osmosis System include:

The tailored blending process removes just the right amount of dissolved solids from the incoming tap water to achieve the desired final water quality. High recovery reverse osmosis technology yields significant savings in water and sewer charges with a minimal environmental footprint. With the average recovery of 78%, the MRS-600HE system only disposes approximately 1/4 cup of water for each cup of water dispensed.

Mineral Reduction System for foodservice applications including coffee brewers, espresso machines, steamers, combi ovens, and ice – ideal for specialty coffee.

  • Requires less than 50% of the electrical energy typically consumed by conventional reverse osmosis systems
  • On board storage tank provides ample reserve capacity for most applications
  • For increased reserve capacity, Everpure offers a complete line of storage tanks
  • Reduces limescale build-up that can cause excessive machine downtime and increased maintenance costs
  • Reduces chlorine taste and odor and other contaminants that can adversely affect the taste of water and beverages

Specifications:

  • Overall Dimensions: 32″ H x 23″ W x 13.6″ D 813 mm H x 584 mm W x 345 mm D [Add 3″ (76 mm) on all 4 sides for cover removal and service access]
  • Inlet and outlet connection: 3/8″ (9.5 mm) OD tube connection
  • Wastewater line connection: 3/8″ (9.5 mm) OD tube connection
  • Daily Production Rate:
    • Processor Only (no blend):
      • 600 gpd (2,271 lpd) nominal
      • 0.417 gpm (1.58 lpm) nominal
    • Processor with Blend:
      • 600 gpd (2,271 lpd) nominal
      • (plus tap water addition)
  • Total daily production rate will vary based on tap water TDS, RO percent rejection and desired blend water TDS – Contact Filterpure for assistance estimating this total
  • Service Flow Rate: Dependant on water pressure in storage tank and line size(s) to equipment
  • Pressure Requirements:
    • Operating: 25 – 80 psi (1.72-5.52 bar), non-shock
    • [Pressure below 50 psi (3.45 bar) may affect blend system performance]
    • Maximum Static: 100 psi (6.89 bar), non-shock
  • Available Voltages and Power Cord Types
    • 115VAC/60Hz – NEMA 5-15P Plug
    • 220VAC/50Hz – GB 2099 Plug
    • 230VAC/50Hz – “Schuko” CEE 7/7 Plug
    • 240VAC/50Hz – AS 3112 Plug
  • Minimum Water Supply: 1.5 gpm (5.7 lpm)
  • Inlet Temperature: 40–100°F (4–38°C)
  • Inlet TDS: 1000 ppm max. recommended

Replacement cartridges:

  • 1 x MR-600 EV9617-13
  • 2 x MC2 EV9612-56
  • 3 x 7FS-BW EV9627-16

Operation Tips

  • Change filter cartridges on a regular 6-month preventative maintenance program
  • Change RO cartridges on a regular 2-year preventative maintenance program
  • Change cartridges when capacity is reached
  • Always flush the filter cartridge at time of installation and cartridge change
  • Proper pre-treatment is required to control RO Cartridge (membrane) scale formation and/or fouling
    • Raw water hardness in excess of 7 grains per gallon should be softened
    • The raw water may contain particulates and the use of a pre-filter is recommended
  • Contact EVERPURE Technical Service for pre-treatment recommendations

Installation Tips

  • Choose a mounting location suitable to support the full weight of the system when operating
  • Deliming of equipment prior to application is recommended
  • Never use saddle valve for connection 
  • Use 3/8” (10 mm) water line
  • The water inlet must supply a minimum of 0.7 gpm (2.7 lpm)
  • Install vertically with cartridge hanging down and allow 2 inches above and below unit for cover removal and service access
  • Allow clearance to right of unit for optional prefilter
  • Refer to Installation, Operation & Maintenance Manual for cartridge flushing and RO start-up

Contact FilterPure for additional product information at 1-800-942-7873.
Download the Everpure MRS-600HE-II EV9970-54 Reverse Osmosis System Specification Sheet

Everpure EV9970-73 MRS-100BL Blended Reverse Osmosis System

The Everpure EV9970-73 MRS-100BL Blended Reverse Osmosis System features:

  • Mineral Reduction System generating 100 gallons per day. 
  • The BL Series features an adjustable blend valve, which allows custom tailoring of the dissolved mineral content in the treated water. 
  • This feature allows a controlled amount of raw water to be mixed with the Reverse Osmosis water to create a blend containing the desired level of TDS (Total Dissolved Solids). After blending, the water passes through a sub-micron carbon filter. This final filtration step removes tastes and odors, and insures delivery of ingredient quality water. “CC” models introduce a small amount of hardness minerals back into the treated water. Improves equipment life and performance by removing at least 90%+ of all dissolved solids that cause scale build-up.
  • Guards against taste and odor causing contaminants while removing dirt, particulates and dissolved minerals that can adversely affect taste of water and beverages. 


Specifications: 

  • Overall Dimensions Inches : 38″ H x 15″ W x 8″ D. Overall Demensions Centimeters (CM): 96.5H X 38.1W X 20.3 D. Voltages:115VAC/60Hz (NEMA 5-15P Plug). 230VAC/50Hz (CEE 7/7 Plug). 240VAC/50Hz (AS 3112 Plug). 
  • Inlet and outlet connection: 3/8″ OD tube connection. 
  • Wastewater line connection: 1/4″ OD tube connection. 
  • Service Flow Rate: Dependant on water pressure in storage tank and line size(s) to equipment. 


Pressure Requirements: 

  • Operating: 25 – 80 psi (172-552 kPa), non-shock. Maximum Static: 100 psi (689 kPa), non-shock. 
  • Water Supply: 0.7 gpm (2.7 lpm). 
  • Inlet Temperature: 40F – 100F (4-38C). 
  • Inlet TDS: 1,500 ppm max recommended. 
  • Operating Weight: 35 lbs. (15.9 kg.)(not including storage tanks). 
  • REQUIRES STORAGE TANK – Everpure offers a complete line of storage tanks.

For more information on this product, contact FilterPure at 1-800-942-7873.


Download the Everpure EV997073 MRS-100BL Blended Reverse Osmosis System Specification Sheet

Everpure MRS-600HE EV9970-38 Reverse Osmosis System

Features of the Everpure MRS-600HE EV9970-38 Reverse Osmosis System:

The tailored blending process removes just the right amount of dissolved solids from the incoming tap water to achieve the desired final water quality. High recovery reverse osmosis technology yields significant savings in water and sewer charges with a minimal environmental footprint. With the average recovery of 78%, the MRS-600HE system only disposes approximately 1/4 cup of water for each cup of water dispensed.

Mineral Reduction System for foodservice applications including coffee brewers, espresso machines, steamers, combi ovens, and ice – ideal for specialty coffee.

  • Requires less than 50% of the electrical energy typically consumed by conventional reverse osmosis systems
  • On board storage tank provides ample reserve capacity for most applications
  • For increased reserve capacity, Everpure offers a complete line of storage tanks
  • Reduces limescale build-up that can cause excessive machine downtime and increased maintenance costs
  • Reduces chlorine taste and odor and other contaminants that can adversely affect the taste of water and beverages

Specifications:

  • Overall Dimensions: 32″ H x 23″ W x 13.6″ D 813 mm H x 584 mm W x 345 mm D [Add 3″ (76 mm) on all 4 sides for cover removal and service access]
  • Inlet and outlet connection: 3/8″ (9.5 mm) OD tube connection
  • Wastewater line connection: 3/8″ (9.5 mm) OD tube connection
  • Daily Production Rate:
    • Processor Only (no blend):
      • 600 gpd (2,271 lpd) nominal
      • 0.417 gpm (1.58 lpm) nominal
    • Processor with Blend:
      • 600 gpd (2,271 lpd) nominal
      • (plus tap water addition)
  • Total daily production rate will vary based on tap water TDS, RO percent rejection and desired blend water TDS – Contact Filterpure for assistance estimating this total
  • Service Flow Rate: Dependant on water pressure in storage tank and line size(s) to equipment
  • Pressure Requirements:
    • Operating: 25 – 80 psi (1.72-5.52 bar), non-shock
    • [Pressure below 50 psi (3.45 bar) may affect blend system performance]
    • Maximum Static: 100 psi (6.89 bar), non-shock
  • Available Voltages and Power Cord Types
    • 115VAC/60Hz – NEMA 5-15P Plug
    • 220VAC/50Hz – GB 2099 Plug
    • 230VAC/50Hz – “Schuko” CEE 7/7 Plug
    • 240VAC/50Hz – AS 3112 Plug
  • Minimum Water Supply: 1.5 gpm (5.7 lpm)
  • Inlet Temperature: 40–100°F (4–38°C)
  • Inlet TDS: 1000 ppm max. recommended

Operation Tips

  • Change filter cartridges on a regular 6-month preventative maintenance program
  • Change RO cartridges on a regular 2-year preventative maintenance program
  • Change cartridges when capacity is reached
  • Always flush the filter cartridge at time of installation and cartridge change
  • Proper pre-treatment is required to control RO Cartridge (membrane) scale formation and/or fouling
    • Raw water hardness in excess of 7 grains per gallon should be softened
    • The raw water may contain particulates and the use of a pre-filter is recommended
  • Contact FILTERPURE Technical Service for pre-treatment recommendations

Installation Tips

  • Choose a mounting location suitable to support the full weight of the system when operating
  • Deliming of equipment prior to application is recommended
  • Never use saddle valve for connection 
  • Use 3/8” (10 mm) water line
  • The water inlet must supply a minimum of 0.7 gpm (2.7 lpm)
  • Install vertically with cartridge hanging down and allow 2 inches above and below unit for cover removal and service access
  • Allow clearance to right of unit for optional prefilter
  • Refer to Installation, Operation & Maintenance Manual for cartridge flushing and RO start-up

**Pallet Shipment Only**


For additional product information, please contact FilterPure at 1-800-942-7873.
Download the Everpure MRS-600HE EV9970-38 Reverse Osmosis System Specification Sheet

Everpure MRS-350 EV9970-17 Reverse Osmosis System

The Everpure MRS-350 EV9970-17 Reverse Osmosis System includes:

  • Part Number: EV9970-17 
  • Improves equipment life and performance by removing at least 90%+ of all dissolved solids that cause scale build-up 
  • Guards against taste and odor causing contaminants while removing dirt, particulates and dissolved minerals that can adversely affect taste of water and beverages 
  • Wall mount design allows flexible installation 
  • Reduces limescale build-up that can cause excessive machine downtime and increased maintenance costs 
  • Scale reduction reduces energy costs 
  • “CC” models introduce a small amount of hardness minerals back into the treated water 
  • This controlled re-mineralization is desirable for coffee and other applications that require some hardness to achieve optimum results 
  • Specifications:
    • Overall Dimensions: 30” H (34” H – CC Model) x 15” W (20.5” Wwith Prefilter) x 8“ D 762 mm H (864mm H – CC Model) x 381 mm W (521 mm W with Prefilter) x 203 mm D 
    • Voltages:
      • 115VAC/60Hz (NEMA 5-15P Plug) 
      • 230VAC/50Hz (“Schuko” CEE 7/7 Plug) 
      • 240VAC/50Hz (AS 3112 Plug) 
    • Inlet and outlet connection: 3/8″ OD tube connection 
    • Wastewater line connection: 1/4″ OD tube connection 
    • Service Flow Rate: Dependant on water pressure in storage tankand line size(s) to equipment 
    • Pressure Requirements:
      • Operating: 25 – 80 psi (172-552 kPa), non-shock 
      • Maximum Static: 100 psi (689 kPa), non-shock 
      • Water Supply: 0.7 gpm (2.7 lpm) 
    • Inlet Temperature: 40°F – 100°F (4-38°C) 
    • Inlet TDS: 1,500 ppm max recommended 
    • Operating Weight: 35 lbs. (15.9 kg.)(not including storage tanks)

Operation Tips

  • Change filter cartridges on a regular 6-month preventative maintenance program
  • Change RO cartridges on a regular 2-year preventative maintenance program
  • Change cartridges when capacity is reached
  • Always flush the filter cartridge at time of installation and cartridge change
  • Proper pre-treatment is required to control RO Cartridge (membrane) scale formation and/or fouling
    • Raw water hardness in excess of 7 grains per gallon should be softened
    • The raw water may contain particulates and the use of a pre-filter is recommended
  • Contact EVERPURE Technical Service for pre-treatment recommendations

Installation Tips

  • Choose a mounting location suitable to support the full weight of the system when operating
  • Deliming of equipment prior to application is recommended
  • Never use saddle valve for connection 
  • Use 3/8” (10 mm) water line
  • The water inlet must supply a minimum of 0.7 gpm (2.7 lpm)
  • Install vertically with cartridge hanging down and allow 2 inches above and below unit for cover removal and service access
  • Allow clearance to right of unit for optional prefilter
  • Refer to Installation, Operation & Maintenance Manual for cartridge flushing and RO start-up

Contact FilterPure at 1-800-942-7873 for additional product information.

Download the Everpure MRS-350 EV9970-17 Reverse Osmosis System Specification System

Everpure MRS-350BL EV9970-20 Reverse Osmosis System

Everpure MRS-350BL EV9970-20 Reverse Osmosis System includes:

The BL Series features an adjustable blend valve, which allows custom tailoring of the dissolved mineral content in the treated water. With this feature, a controlled amount of raw water is mixed with the Reverse Osmosis water to create a blend containing the desired level of TDS (Total Dissolved Solids). After blending, the water passes through a sub-micron carbon filter. This final filtration step removes tastes and odors, and insures delivery of ingredient quality water.

  • Part Number: EV9970-20
  • “CC” models introduce a small amount of hardness minerals back into the treated water
  • Improves equipment life and performance by removing at least 90%+ of all dissolved solids that cause scale build-up
  • Guards against taste and odor causing contaminants while removing dirt, particulates and dissolved minerals that can adversely affect taste of water and beverages
  • Wall mount design allows flexible installation
  • Reduces limescale build-up that can cause excessive machine downtime and increased maintenance costs
  • Scale reduction reduces energy costs
  • This controlled re-mineralization is desirable for coffee and other applications that require some hardness to achieve optimum results
  • Specifications:
    • Overall Dimensions: 30” H (34” H – CC Model) x 15” W (20.5” Wwith Prefilter) x 8“ D 762 mm H (864mm H – CC Model) x 381 mm W (521 mm W with Prefilter) x 203 mm D
    • Voltages:
      • 115VAC/60Hz (NEMA 5-15P Plug)
      • 230VAC/50Hz (“Schuko” CEE 7/7 Plug)
      • 240VAC/50Hz (AS 3112 Plug)
    • Inlet and outlet connection: 3/8″ OD tube connection
    • Wastewater line connection: 1/4″ OD tube connection
    • Service Flow Rate: Dependant on water pressure in storage tankand line size(s) to equipment
    • Pressure Requirements:
      • Operating: 25 – 80 psi (172-552 kPa), non-shock
      • Maximum Static: 100 psi (689 kPa), non-shock
      • Water Supply: 0.7 gpm (2.7 lpm)
    • Inlet Temperature: 40°F – 100°F (4-38°C)
    • Inlet TDS: 1,500 ppm max recommended
    • Operating Weight: 35 lbs. (15.9 kg.)(not including storage tanks)

Operation Tips

  • Change filter cartridges on a regular 6-month preventative maintenance program
  • Change RO cartridges on a regular 2-year preventative maintenance program
  • Change cartridges when capacity is reached
  • Always flush the filter cartridge at time of installation and cartridge change
  • Proper pre-treatment is required to control RO Cartridge (membrane) scale formation and/or fouling
    • Raw water hardness in excess of 7 grains per gallon should be softened
    • The raw water may contain particulates and the use of a pre-filter is recommended
  • Contact EVERPURE Technical Service for pre-treatment recommendations

Installation Tips

  • Choose a mounting location suitable to support the full weight of the system when operating
  • Deliming of equipment prior to application is recommended
  • Never use saddle valve for connection 
  • Use 3/8” (10 mm) water line
  • The water inlet must supply a minimum of 0.7 gpm (2.7 lpm)
  • Install vertically with cartridge hanging down and allow 2 inches above and below unit for cover removal and service access
  • Allow clearance to right of unit for optional prefilter
  • Refer to Installation, Operation & Maintenance Manual for cartridge flushing and RO start-up

For more product information, please call FilterPure at 1-800-942-7873.

Download the Everpure MRS-350BL EV9970-20 Reverse Osmosis System Specification Sheet

Everpure MRS-100 EV9970-07 Reverse Osmosis System

Everpure MRS-100 EV9970-07 Reverse Osmosis System features:

  • Part Number: EV9970-07 
  • Mineral Reduction System for foodservice applications 
  • Capacity: 100 gpd 
  • Ideal for:
    • Flash steamers 
    • Conventional steamers 
    • Cheese melters 
    • Combi-ovens 
    • Coffee/espresso machines 
  • Improves equipment life and performance by removing at least 90%+ of all dissolved solids that cause scale build-up 
  • Guards against taste and odor causing contaminants while removing dirt, particulates and dissolved minerals that can adversely affect taste of water and beverages 
  • Sanitary cartridge replacement is simple, quick and clean. Internal filter parts are never exposed to handling or contamination

MRS-100 RO System

Operation Tips

  • Change filter cartridges on a regular 6-month preventative maintenance program
  • Change RO cartridges on a regular 2-year preventative maintenance program
  • Change cartridges when capacity is reached
  • Always flush the filter cartridge at time of installation and cartridge change
  • Proper pre-treatment is required to control RO Cartridge (membrane) scale formation and/or fouling
    • Raw water hardness in excess of 7 grains per gallon should be softened
    • The raw water may contain particulates and the use of a pre-filter is recommended
  • Contact EVERPURE Technical Service for pre-treatment recommendations

Installation Tips

  • Choose a mounting location suitable to support the full weight of the system when operating
  • Deliming of equipment prior to application is recommended
  • Never use saddle valve for connection 
  • Use 3/8” (10 mm) water line
  • The water inlet must supply a minimum of 0.7 gpm (2.7 lpm)
  • Install vertically with cartridge hanging down and allow 2 inches above and below unit for cover removal and service access
  • Allow clearance to right of unit for optional prefilter
  • Refer to Installation, Operation & Maintenance Manual for cartridge flushing and RO start-up

Contact FilterPure at 1-800-942-7873 for additional product information.
Download the Everpure MRS-100 EV9970-07 Reverse Osmosis System Specification Sheet

Everpure MRS EV9795-81 Prefilter System

Everpure MRS EV9795-81 Prefilter System includes:

  • Part Number: EV9795-81
  • Filters out larger dirt and rust particles
  • Extends the life of primary filter cartridges
  • EC110 sediment cartridge delivers 10 micron nominal filtration
  • 10″ bowl design accepts most 10″ drop in cartridges
  • Update 2017: Now with Black Bowl/Sump

Specifications:

  • Overall Dimensions: 12.44”H x 5.16”W x 5.5”D
  • Inlet connection: 3/4” 
  • Outlet connection: 3/4”
  • Service Flow Rate: Maximum 6.0 gpm (22.7 Lpm)
  • Pressure Requirements: 10 – 125 psi (0.7 – 8.6 bar), non-shock

Contact FilterPure at 1-800-942-7873 for additional product information and replacement cartridges.