Description
Features of the Everpure MRS-100CC-BL EV9973-63 Reverse Osmosis System include:
- Part Number: EV9973-63 (Old EV9970-10)
- Improves equipment life and performance by removing at least 90%+ of all dissolved solids that cause scale build-up
- Guards against taste and odor causing contaminants while removing dirt, particulates and dissolved minerals that can adversely affect taste of water and beverages
- Wall mount design allows flexible installation
- Reduces limescale build-up that can cause excessive machine downtime and increased maintenance costs
- Scale reduction reduces energy costs
- “CC” models introduce a small amount of hardness minerals back into the treated water
- This controlled re-mineralization is desirable for coffee and other applications that require some hardness to achieve optimum results
- Specifications:
- Overall Dimensions: 30” H (34” H – CC Model) x 15” W (20.5” Wwith Prefilter) x 8“ D 762 mm H (864mm H – CC Model) x 381 mm W (521 mm W with Prefilter) x 203 mm D
- Voltages:
- 115VAC/60Hz (NEMA 5-15P Plug)
- 230VAC/50Hz (“Schuko” CEE 7/7 Plug)
- 240VAC/50Hz (AS 3112 Plug)
- Inlet and outlet connection: 3/8″ OD tube connection
- Wastewater line connection: 1/4″ OD tube connection
- Service Flow Rate: Dependant on water pressure in storage tankand line size(s) to equipment
- Pressure Requirements:
- Operating: 25 – 80 psi (172-552 kPa), non-shock
- Maximum Static: 100 psi (689 kPa), non-shock
- Water Supply: 0.7 gpm (2.7 lpm)
- Inlet Temperature: 40°F – 100°F (4-38°C)
- Inlet TDS: 1,500 ppm max recommended
- Operating Weight: 35 lbs. (15.9 kg.)(not including storage tanks)
Operation Tips
- Change filter cartridges on a regular 6-month preventative maintenance program
- Change RO cartridges on a regular 2-year preventative maintenance program
- Change cartridges when capacity is reached
- Always flush the filter cartridge at time of installation and cartridge change
- Proper pre-treatment is required to control RO Cartridge (membrane) scale formation and/or fouling
- Raw water hardness in excess of 7 grains per gallon should be softened
- The raw water may contain particulates and the use of a pre-filter is recommended
- Contact EVERPURE Technical Service for pre-treatment recommendations
Installation Tips
- Choose a mounting location suitable to support the full weight of the system when operating
- Deliming of equipment prior to application is recommended
- Never use saddle valve for connection
- Use 3/8” (10 mm) water line
- The water inlet must supply a minimum of 0.7 gpm (2.7 lpm)
- Install vertically with cartridge hanging down and allow 2 inches above and below unit for cover removal and service access
- Allow clearance to right of unit for optional prefilter
- Refer to Installation, Operation & Maintenance Manual for cartridge flushing and RO start-up
Contact FilterPure at 1-800-942-7873 for additional product information.
Download the