Posted on

How To Stop Slime!

Is slime taking over your ice machines? Don’t worry, slime contamination can be solved with the correct water filtration system. In a hospital, various environmental factors affect the ice. The problem with slime originates from filtration removing the disinfectant from the supply water to the ice machine.  By removing chlorine and chloramines, contamination can occur in the ice bins and nasty bacteria can multiply, leaving you with SLIME! To address this problem, Everpure has developed the 7SI cartridge. Everpure’s 7SI cartridge (EV9606-01) allows chlorine or chloramines through to help fight slime. 

7SI Cartridge

  • Specializes in slime and bacteria growth prevention
  • Reduces particulates down to 0.5 micron
  • Utilizes depth filtration and Fiberdyne™ media for superior dirt holding capability
  • Leaves chlorine and chloramines within water that is supplied to equipment which helps to reduce slime and bacteria growth in applications
  • Reduces system maintenance, service costs and buildup. Scale, slime, and bacteria growth can result in clogging of distribution lines, malfunction of probes, floats, pumps, solenoids and valves, and higher energy consumption
  • Sanitary cartridge replacement is simple, quick and clean. Internal filter parts are never exposed to handling or contamination
  • Can be used on Insurice® and Hybrid Manifold Systems
  • NSF® Certified under NSF / ANSI Standards 42 and 53

Features:

  • Cyst Reduction
  • Particulate Reduction
  • Capacity: 25,000 gallons (94,635 liters)
  • Maximum Flow: 3.5 gpm (13.25 lpm)
  • Qty. per Case: 0
  • Working Pressure: 10 – 125 psi (0.7 – 8.6 bar), non-shock
  • Max. Temp: 35 – 100ºF (2 – 38ºC)
  • H: 20.75″ D: 3.25″ Certifications: NSF42 NSF53

The 7SI cartridge is Everpure’s response to the ever-changing demands in the water filtration industry.  By keeping the disinfectant properties of chlorine in the water supply, we have removed the problem of slime without requiring additional costly equipment. If you are dealing with slime in your ice machines or another problem that just cannot be solved, contact us! We’ll help you find a solution. Call us at 800-942-7873.

Posted on 1 Comment

How Filtration Can Go Wrong

A couple years ago, a luxury hotel had attempted to filter their entire water supply. Their desire was to provide their guest with the best experience possible.  While with good intentions this also gave way to some negative consequences.  Understanding what to remove and what to leave in your water supply can affect not just the taste and odor of the water, but the safety of the water as well.  This particular facility had wanted to remove all the chlorine from their incoming water supply and made the decision to utilize a whole building system to do so.  The side effect of removing all antibacterial properties in a large water system is the introduction of bacterial growth after the point of entry system.  This bacteria growth will occur in the piping after the filtration system and will cause exposure to the user’s downstream. What Filter Pure would have recommended was utilizing a mechanical filtered system with Ultraviolet at the point of entry. This would eliminate any possible contaminants entry into the building water supply.  It also maintains the appropriate levels of disinfectant to ensure pipes are not permitting bacterial growth. For taste and odor concern, these should always be handled at the point of use with a system similar to the Insurice Single PF-i2000 system (EV9324-21).  We recommend Everpure for all water point of use systems. Every location has different water quality concerns that require direct and special attention. If you have any questions regarding your facility’s water filtration systems, please contact me, Todd Leach, or our customer service team at 1-800-942-7873. Ask me a questions!

Posted on 1 Comment

Legionella: The Silent Killer!

In the last year, over 400 people have been infected by a water born bacteria called Legionella.  Over 30 of those infected died. What’s more shocking than those numbers is the fact that those outbreaks took place in hospitals, retirement communities, theme parks, and hotels.   An estimated 8,000 to 18,000 people are hospitalized with Legionnaires’ disease each year in the U.S. How can so many people be infected by this bacteria, especially in places where you think you would be safe from any deadly bacteria? Being exposed to any water system can be a source of disease if the water in it is subjected to conditions that promote growth of the organism. 

 In Strong Memorial Hospital, Rochester, NY, multiple people developed Legionnaires disease; case investigation and environmental culture surveillance found that the Legionella bacteria came from the ice machine. One 66-year old patient, who was making a slow recovery from cancer, died from the outbreak due to inhalation of the aerosols released from the ice chips he was consuming. 

So how do you kill Legionella?

First, is preventing it! Killing the bacteria before it reaches any water system. Traditional oxidizing agents such as chlorine have been proven very effective in controlling Legionella. Using continuous chlorination at low free residual levels can be effective in controlling Legionella. That’s why many hospitals are using Everpure’s 7SI cartridges on their ice machines to help prevent the Legionella bacteria from forming in their water.

7SI Cartridge

  • Specializes in slime and bacteria growth prevention
  • Reduces particulates down to 0.5 micron
  • Utilizes depth filtration and Fiberdyne™ media for superior dirt holding capability
  • Leaves chlorine and chloramines within water that is supplied to equipment which helps to reduce slime and bacteria growth in applications
  • Reduces system maintenance, service costs and buildup. Scale and slime, as well as, bacteria growth can result in clogging of distribution lines, malfunction of probes, floats, pumps, solenoids and valves, and higher energy consumption
  • Sanitary cartridge replacement is simple, quick and clean. Internal filter parts are never exposed to handling or contamination
  • Can be used on Insurice® and Hybrid Manifold Systems
  • NSF® Certified under NSF / ANSI Standards 42 and 53

Features:

  • Cyst Reduction
  • Particulate Reduction
  • Capacity: 25,000 gallons (94,635 liters)
  • Maximum Flow: 3.5 gpm (13.25 lpm)
  • Qty. per Case: 0
  • Working Pressure: 10 – 125 psi (0.7 – 8.6 bar), non-shock
  • Max. Temp: 35 – 100ºF (2 – 38ºC)
  • H: 20.75″ D: 3.25″ Certifications: NSF42 NSF53
Contact us for more information on the 7SI cartridge and how to stop Legionella.